Lithium Cells & Custom Battery Packs

Custom packs

Custom battery packs

Define the loads, enclosure and interfaces your equipment needs. For cold or wet sites, add the expected temperature and water exposure to the brief.

View project checklist

PACK SOLUTIONS

Choose the condition that sets your pack requirements

Start with the closest fit. If high current, cold and water exposure overlap, put them in the same enquiry.

REPEATED PEAK LOADS

High-current equipment packs

For equipment with motor starts, lifting or repeated actuator peaks. Start with the load at operating voltage, not the motor nameplate alone.

What to share
Voltage window, running current, peak current, pulse duration and repetition.
What we would verify
Minimum loaded voltage, temperature rise and the protection response at the agreed duty cycle.
View solution

COLD START AND CHARGE

Low-temperature packs

For equipment that must start or run after a cold soak. Set separate temperature requirements for discharge and charging.

What to share
Coldest start and charge temperatures, soak time, runtime and the charging location.
What we would verify
Loaded voltage during cold start, usable runtime and charger behaviour with the complete pack.
View solution

RAIN, SPLASH AND WASHDOWN

Water exposure and washdown packs

For installations with rain, spray or cleaning exposure. Describe how the enclosure and its connections are installed and used.

What to share
Type of water exposure, pressure or immersion details if relevant, mounting and connector state.
What we would verify
Ingress performance of the assembled enclosure in the intended mounting and connector configuration.
View solution

Standard Pack enquiry briefs

Use these repeatable briefs to specify a project. They are not stock models or validated ratings.

HC-EQUIPMENT

High-current equipment brief

Example input: a 48 V equipment class with a motor start or actuator peak. Supply the actual operating voltage range and timed current trace.

BMS and protections
Agree cell voltage, current and temperature protections; define trip delay, recovery and safe behaviour during repeated peaks or communications loss.
Interfaces
Specify charger, mating power connector and harness, startup or precharge needs, host signals and CAN or other protocol only if required.
Acceptance boundary
Document continuous current separately from a timed peak and any intermediate overload. State test temperature, state of charge, minimum loaded voltage, peak duration, rest interval, repeat count and protection response. No blanket current rating.
Review this brief

LT-SOAK

Cold-soak and recovery brief

Example input: equipment starts after a −20°C soak and is moved to a warmer charging area. The example is a requirement, not a pack rating.

BMS and protections
Define sensor locations and measurement tolerance; agree separate discharge and charge inhibit limits, release hysteresis and charger behaviour after warm-up.
Interfaces
Identify charger, temperature reporting and load disconnect. If heating is requested, document its energy, source, control and fault response separately.
Acceptance boundary
Measure startup voltage and usable runtime after cold soak. Record ambient and measured cell temperatures separately. If a heater is specified, verify charge inhibition until the cells reach the agreed temperature; heater power is not cell charging current. No general subzero charge claim.
Review this brief

WE-EXPOSURE

Washdown and rain-exposure brief

Example input: installed enclosure sees fresh-water cleaning with connectors mated and service covers closed. State method, chemistry, duration and mounting.

BMS and protections
Agree response to moisture-related fault indications and safe restart after service; protection electronics do not qualify the enclosure.
Interfaces
Define mating connectors and caps, gasketed covers, vents, drain paths, orientation and whether a connector is exposed when unmated.
Acceptance boundary
Record whether an ingress result covers the electronics compartment or the assembled pack, including connectors, vent, covers and installation orientation. Identify the exposure method, duration, and mated or capped state. Spray results do not establish immersion protection.
Review this brief

Priority Pack applications

Use these design briefs to start a project. They do not represent stocked models, customer installations or certified configurations.

Additional Pack applications

Choose the equipment and environment that best match the project, then request an engineering review.

Start with the equipment

Share the operating voltage, steady and peak draw, peak duration, runtime and available space. Confirm any integration or documentation needs before treating a configuration as available.

  • Electrical load and voltage window
  • Mechanical fit, connections and service access
  • Charging, monitoring and documentation
Pack enclosure study with handles, front connector and mounting feet

Pack capabilities to discuss

These are project paths, not standard stock models.

Compact & removable packs

Review enclosure limits, retention or exchange mechanism, charging arrangement and service access.

Use for applications where the battery is expected to be swapped or installed in a constrained compartment.

Industrial enclosure packs

Capture mounting dimensions, connector position, environment and service access.

Enclosure material and protective ratings are project-specific and issued only for verified configurations.

Short-duration high-power packs

Define peak current together with duration, repetition, temperature and minimum operating voltage.

A single pulse without its conditions cannot establish usable pack performance.

BMS & interfaces

List controls, protection needs, interfaces and whether the equipment requires documented communication.

A communication interface, protection setting or compatibility is confirmed against the actual project, not assumed.

Modular pack systems

Describe the requested electrical envelope, service or redundancy needs, and system architecture.

Series or parallel integration is available for review as a project path, not a published claim of a standard platform.

From cell choice to pack assembly

Review electrical topology, protective controls, the enclosure, interface and test plan together. A cell current rating does not establish pack output.

Concept illustration of pack enclosure, module and protection system
Engineering illustration, not a released pack configuration.

Example engineering briefs

Illustrative project paths, not customer case studies or delivery claims.

Repeated peaks in mobile automation

A compact, serviceable layout starts with acceleration, lifting and charge duty. Confirm connector access, minimum bus voltage and the release checks.

Equipment exposed to washdown

Specify cleaning direction, pressure, temperature and connector state. Confirm enclosure qualification for the actual mounting arrangement.

CNS BatteryEngineering desk