Example input: a 48 V equipment class with a motor start or actuator peak. Supply the actual operating voltage range and timed current trace.
- BMS and protections
- Agree cell voltage, current and temperature protections; define trip delay, recovery and safe behaviour during repeated peaks or communications loss.
- Interfaces
- Specify charger, mating power connector and harness, startup or precharge needs, host signals and CAN or other protocol only if required.
- Acceptance boundary
- Document continuous current separately from a timed peak and any intermediate overload. State test temperature, state of charge, minimum loaded voltage, peak duration, rest interval, repeat count and protection response. No blanket current rating.