Lithium Cells & Custom Battery Packs

02 / COLD OPERATION

Low-temperature lithium cells

Find cold-weather rechargeable cells by format and capacity. Check the lowest temperature at which your equipment runs and the lowest temperature at which it must charge.

Low-temperature cell finder

Choose a target for one or both operations. The filters use model-specific ranges or exact test points; they do not indicate the current or capacity available at that temperature.

Model range

A listed temperature range. Current may change across the range.

Model test point

One stated temperature and current. It does not imply a range.

Series data only

Shown for reference; excluded from both temperature filters.

25 references

18650

Model range

CNS-INR18650-P3000A

3 Ah · 3.6 V

Discharge
−40°C to +60°C
Charge
0°C to +60°C

21700

Model range

CNS-INR21700-P4200A

4.2 Ah · 3.6 V

Discharge
−40°C to +60°C
Charge
0°C to +45°C

21700

Model range

CNS-INR21700-P4500A

4.5 Ah · 3.6 V

Discharge
−40°C to +60°C
Charge
0°C to +60°C

21700

Model range

CNS-LT-C21-03

4 Ah · 3.6 V

Discharge
−40°C to +80°C
Charge
−20°C to +60°C

21700

Model range

CNS-LT-C21-04

5 Ah · 3.6 V

Discharge
−40°C to +80°C
Charge
−20°C to +60°C

21700 · LFP

Model range

CNS-LT-C21-05

2.6 Ah · 3.2 V

Discharge
−20°C to +80°C
Charge
−10°C to +60°C

4695 cylindrical

Model range

CNS-LT-C46-01

32 Ah · 3.6 V

Discharge
−40°C to +80°C
Charge
−10°C to +60°C

46120 cylindrical

Model range

CNS-LT-C46-02

42 Ah · 3.6 V

Discharge
−40°C to +80°C
Charge
−10°C to +60°C

Prismatic · LFP

Model test point

CNS-LFP-PR-LT40000A

40 Ah · 3.2 V

Discharge
−40°C at 10C
Charge
−20°C at 0.1C

Prismatic

Model range

CNS-LI-PR-LT4000A

4 Ah · 3.65 V

Discharge
−40°C to +85°C
Charge
−30°C to +85°C

Prismatic

Model range

CNS-LI-PR-LT5600A

5.6 Ah · 3.65 V

Discharge
−40°C to +85°C
Charge
−30°C to +85°C

Pouch

Series data only

CNS-LT-PO-01

1.4 Ah · 3.7 V

Discharge
−50°C series example

Pouch

Series data only

CNS-LT-PO-02

1.9 Ah · 3.7 V

Discharge
−50°C series example

Pouch

Series data only

CNS-LT-PO-03

2 Ah · 3.7 V

Discharge
−50°C series example

Pouch

Series data only

CNS-LT-PO-04

2.2 Ah · 3.7 V

Discharge
−50°C series example

Pouch

Series data only

CNS-LT-PO-05

2.35 Ah · 3.7 V

Discharge
−50°C series example

Pouch

Series data only

CNS-LT-PO-06

2.65 Ah · 3.8 V

Discharge
−50°C series example

Pouch

Series data only

CNS-LT-PO-07

2.75 Ah · 3.7 V

Discharge
−50°C series example

Pouch

Series data only

CNS-LT-PO-08

3.05 Ah · 3.7 V

Discharge
−50°C series example

Pouch

Series data only

CNS-LT-PO-09

4 Ah · 3.7 V

Discharge
−50°C series example

Pouch

Series data only

CNS-LT-PO-10

5 Ah · 3.7 V

Discharge
−50°C series example

Pouch

Series data only

CNS-LT-PO-11

6 Ah · 3.7 V

Discharge
−50°C series example

Pouch

Series data only

CNS-LT-PO-12

8.3 Ah · 3.7 V

Discharge
−50°C series example

Pouch

Series data only

CNS-LT-PO-13

19.5 Ah · 3.7 V

Discharge
−50°C series example

Listed cells are available to order through CNS. Request a quote for your quantity and schedule, and verify the exact specifications against your application.

What is the coldest point in your duty cycle?

Send us the lowest temperature for each operation, the steady load, the peak duration and the available space.

CNS BatteryEngineering desk