01 / CURRENT DEMAND
High-rate cells
Compare high-drain and high-discharge-rate cells by format, capacity and continuous current.
Find high-rate cellsBattery cells
Know a model code or size? Search the catalogue. If your equipment runs in the cold, check discharge and charging separately.
Search by model code or filter by size and continuous current. Select two or three models to compare their ratings and conditions.
771 references
Listed cells are available to order through CNS. A dash means a value is not shown here; it cannot pass a minimum filter. Check rating conditions before comparing.
No models match these filters.
01 / CURRENT DEMAND
Compare high-drain and high-discharge-rate cells by format, capacity and continuous current.
Find high-rate cells02 / COLD OPERATION
Screen cold-weather cells by discharge and charging temperature separately.
Find low-temperature cellsCURRENT DEMAND
Choose a format first, then compare the exact model and its documented test conditions.
Compact cylindrical cells for designs where available volume and current draw matter.
Compare power-oriented and higher-capacity cylindrical references in the 21 mm family.
Review 26650 cylindrical cell references by documented load and physical envelope.
Review 26700 cylindrical cell references by documented load and physical envelope.
Review 32140 cylindrical cell references by documented load and physical envelope.
Review 32700 cylindrical cell references by documented load and physical envelope.
Review 46800 cylindrical cell references by documented load and physical envelope.
Review 4695 cylindrical cell references by documented load and physical envelope.
Review 46120 cylindrical cell references by documented load and physical envelope.
Large cylindrical references in the 4695 and 46120 formats, with distinct capacity and discharge profiles.
Rectangular enclosure formats for applications that need verified current output and defined mounting space.
Flat cell formats for designs that need a different footprint, thickness or terminal arrangement.
Compare the formats and operating limits, then request samples or a volume quote for your chosen model.
18650 · high-rate
30 A continuous with an 80°C cutoff. Do not use this as a cold-current rating.
21700 · high-rate
60 A continuous with an 80°C cutoff. The published temperature range is not a full-current envelope.
Pouch · high-rate
102 A continuous; the 153 A pulse is up to 30 seconds. The source requires external clamping at 30 psi.
Prismatic · high-rate
400 A is calculated from 4C and rated capacity. Check the exact source and the separate pulse protocol.
Prismatic · low-temperature
The manufacturer asks for consultation below 0°C. Room-temperature cycle figures do not describe cold life.
Check the model limits and request samples or a quote for your project.
18650 · general maximum
The source lists a 35 A maximum; it does not establish a continuous rating. Its cold curve uses 2.8 A after charging at 23°C.
21700 · high-rate
The 45 A continuous rating and the 4.2 A cold-test curve are different conditions.
21700 · high-rate
45 A continuous with an 80°C cutoff. The published temperature range does not rate output at 45 A throughout.
Prismatic · low-temperature test points
The source reports a −40°C discharge point at 10C and a separate −20°C charge point at 0.1C. These are not an operating range.
Prismatic · low-temperature
The 8 A recommended maximum is not a rating at the cold endpoints. Typical cycle data is measured at +25°C, not in the cold.
26650 · high-rate LFP
52 A maximum continuous and 120 A for 10 seconds are distinct ratings. Subzero charging requires a separate approved protocol.
Prismatic · 50 Ah LFP
500 A is derived from the published 10C maximum continuous rating. The listed 15C peak has no stated duration in the exact model table.
Prismatic · 50 Ah LFP
300 A is derived from the published 6C maximum continuous rating. The source does not consistently specify a peak rating.
Prismatic · 100 Ah LFP
600 A is derived from the 6C maximum continuous rating; 8C for 30 seconds is a separate pulse at 50% state of charge.