LT-SOAK
Cold-soak and recovery brief
Example input: equipment starts after a −20°C soak and is moved to a warmer charging area. The example is a requirement, not a pack rating.
- BMS and protections
- Define sensor locations and measurement tolerance; agree separate discharge and charge inhibit limits, release hysteresis and charger behaviour after warm-up.
- Interfaces
- Identify charger, temperature reporting and load disconnect. If heating is requested, document its energy, source, control and fault response separately.
- Acceptance boundary
- Measure startup voltage and usable runtime after cold soak. Record ambient and measured cell temperatures separately. If a heater is specified, verify charge inhibition until the cells reach the agreed temperature; heater power is not cell charging current. No general subzero charge claim.