Write down the full load trace
Record the continuous level, peak amplitude and duration, minimum rest time, number of repetitions and minimum voltage the host can accept. Capture the case that matters at low state of charge, cold soak or limited cooling.
Convert ratings only when the basis is known
For a 5 Ah reference, 20 A divided by 5 Ah equals 4C. This is a conversion example, not a current rating. Compare it to a documented continuous or time-limited rating at comparable test conditions, including cutoff and temperature.
Test the complete pack
Evaluate the pack under the representative trace with its proposed BMS, connectors, mounting and cooling. Check voltage sag, local temperature rise and protection recovery after repeated peaks. One isolated pulse does not establish repeated performance.